Wednesday, September 30, 2009

Codes:

Basic Features

Building Classification: M (mercantile)

Construction Type: Type III B

noncombustible exterior

combustible interior supports

                        2 Exterior bearing walls

                        0 Interior bearing walls

 Exiting

Occupant load per floor:

            Basement: 53  

First: 53

            Second: 26

 Required exits for each space:

            2 per floor above grade

 Exit table

 Exit Access: Table

 Arrangements of width of exits:

            3’ minimum

 Minimum Travel Distance:

The straight path between two exits should be at least half the diagonal distance of the entire space (the longest diagonal possible)

 Distance between exits should not exceed 200’ without sprinklers. With the addition of sprinklers, the distance between exits can be increased.

 Corridors (minimum width): 3’

The staircase would be required to be rated, as it serves entire floors. A 1 hour fire rating is the minimum, as the occupancy is greater than 30 on 2 levels.

 Doors:

            Door opening minimum is 32”

 Barrier-Free Design (ADA)

Accessibility Route:

            Location: At least ADA compliable route from exterior

            Width: The minimum width of an accessible route is 36”

            Passing Space: 5’x5’ passing/turnaround space minimum

            Head Room: Space shall have 80” clearance

            Surface Textures: Surfaces should be stable, firm, and slip resistant

            Doors: Clear openings of 32” should be provided

            Egress: Accessible route from the exterior will be used as the egress

 Plumbing Fixtures & Toilet Rooms:

            Sinks: Sinks shall be mounted no higher than 34” above the finish floor

            Water Closet: The height of water closets shall be 17-19”, measured from the top of the                toilet seat.

            Drinking Fountains: 50% or more should be ADA compliable.

 Floor Surfaces:

            Surfaces should be stable, firm, and slip-resistant.

 Protruding Objects:

            Objects shall not protrude from walls more than 4” into walks, halls, corridors, passageways, or aisles.

 Detectable Warnings:

            Detectable warnings shall consist of a surface of truncated domes aligned in a square grid pattern. Contrast to regular surface is key.

 Signage and Alarms:

            Letters and numbers on signs shall have a width-to-height ratio between 3:5 and 1:1 and a stroke-width-to-height-ratio between 1:5 and 1:10.

 Seating (Accessible wheelchair spaces):

            If seating spaces for people in wheelchairs are provided at fixed tables or counters, clear floor space shall be provided.

 Plumbing System Requirements

Lavatory: 1 per 750 occupancy

Drinking Fountain: 1 per 1,000 occupancy

Other: Service sink

Signage: Legible sign designating sex shall placed in a visible location.

 Sound Rating Requirements

Indoor Classification Sound Levels:

Environment: General Office

Subjective Evaluations: Moderate

Sound Level (DBA): 60

 Schematic Design:

Wayfinding:

Node

Central Pathway

Glass wall displays the stars to the various levels

Furniture Arrangement

Lighting

Signage

Display Windows

 

Minimum Dimensional Requirements:

Reception: 144sf

Node: 60sf

Showroom: 816sf

Conference: 350sf

Office: 450sf

Lounge: 190sf

Bathroom: 72sf

 

2082

x  .25%

 

2602.5sf

Adjacencies:

   Desired Relationships:

                        Storage/Stairs/Elevator

                        Entrance/Reception

                        Reception/Showroom

                        Showroom/Stairs/Elevator

                        Stairs/Elevator/Office/Lounge

                        Lounge/Bathroom

Lounge/Office

Office/Conference


 

Zoning:         

            Private:                                              

                        Basement Storage                                           

            Work Zone:

                        Office

                        Conference

                        Showroom

            Semi Private:

                        Conference

            Public:

                        Bathroom

                        Showroom

Reception

                        Offices

                        Lounge

Users In Zones:

            Private:

                        Cleaning Staff

                        Employees

            Work Zone:

                        Cleaning Staff

                        Employees

                        Clients

                        Invited Groups for Events

            Semi Private:

                        Clients

                        Employees

Public:

            Universal

Spatial Allocations 



Perspectives


Wednesday, September 23, 2009

Monday, September 21, 2009

Precedent Analysis: Group Review

For this assignment, the class was to pair off into groups and research two showrooms: one actually visited and one found in a magazine or online. For each showroom, we were to create a precedent analysis, determining many aspects of the space. After interacting with the site, or else viewing images of the showrooms, we were to find the concept and how it relates to the circulation, zones, and various structural integrity. 
Once we finished our own precedent studies of the showrooms, we were to critique the content of the other groups' work. The various sites had similarities and drastic differences, but the overall notion of the Showroom purpose kept them connected. 
Concept: It seems that the Showrooms' designs were more about function and circulation than they were clear and abstract conceptual statements. Salone Del Mobile displayed its concept in dramatic designs and the various Apple Store used branding as Conceptual Marketing. The other Showrooms more revolved around the display of the space client perception of the products. 
Generally speaking, the circulation and zoning layout of the Showrooms are influenced by the products as well as the public/private space. The customers and clients are able to interact with the products and move freely without accessibility issues. Other similarities that predominately all spaces had were the color and fixture choices; the showrooms were visually neutral and simple as not to detract from the products. 
From the review of the various groups, we are able to understand the design and conceptual aspects of various Showrooms. It will aid as reference in our continuation and exploration of our product and subsequent design. 

Friday, September 4, 2009

Sunday, August 30, 2009

Wednesday, August 26, 2009

The Nature of Design

Starting off a new year, our studio is taking advantage of the surrounding environments. We are connecting nature to design, so far in the most literal way. The first part of this assignment asked us to find 5 items in nature. From there, we were to observe and note characteristics of the items chosen. Nature and Digital Design combine in the next portion of the assignment, for we are to take two of the items, and recreate their properties in sketchup. 


Pod

Berries


Flowers

Birch Tree Bark


Magnolia Pod




And So It Begins...Third Year

Yet Another Year Starts Up...